Thank you for your interest in NSN part number 1172008P2 under NSN 5945008539070 on Click Aerospace. Click Aerospace is a website owned and operated by ASAP Semiconductor, offering customers access to an unparalleled inventory of premium parts that cater to a variety of industries and applications. Relay Electromagnet is an item listed with the part number 1172008P2, and FSC 5945 Relays and Solenoids and it is manufactured by Bae Systems Information And Electronic Systems Integration Inc having CAGE Code 94117. This item, alongside the rest of our listed NSN parts, is readily available for purchase through our website now. Get started on the purchasing process today by filling out and submitting an Instant RFQ as provided through our website. Once received, a member of our staff will reach out to you in 15 minutes or less to offer a personalized quote based on your individual needs.
Note : We will not share your information to any third parties.
Click Aerospace is a leading independent distributor of NSN part 1172008P2, and we can help you procure NSN components such as 5945008539070 and many more. The quality of our inventory is of the utmost importance to us, and thus we choose to only source our parts from global manufacturers like Bae Systems Information And Electronic Systems Integration Inc. Get started with a competitive quote today when you submit an Instant RFQ and experience how we are revolutionizing the parts procurement process.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-853-9070 Item Description: Relay Electromagnet | 5945 | 008539070 | N | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | 0 | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
1172008p2 | 3 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ELECTROMAGNETIC | ABKW | OVERALL HEIGHT0 430 INCHES NOMINAL |
ELECTROMAGNETIC | ABMK | OVERALL WIDTH0 580 INCHES NOMINAL |
ELECTROMAGNETIC | APCN | COIL QUANTITY1 |
ELECTROMAGNETIC | APNA | WINDING DC RESISTANCE RATING700 0 OHMS NOMINAL SINGLE WINDING |
ELECTROMAGNETIC | APNP | DUTY TYPECONTINUOUS |
ELECTROMAGNETIC | AXHR | MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
ELECTROMAGNETIC | CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT2 POLE DOUBLE THROW ONE POSITION MOMENTARY |
ELECTROMAGNETIC | CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP26 5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
ELECTROMAGNETIC | ABHP | OVERALL LENGTH1 320 INCHES NOMINAL |
ELECTROMAGNETIC | ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1 062 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ELECTROMAGNETIC | ADZC | ENVIRONMENTAL PROTECTIONHERMETIC |
ELECTROMAGNETIC | AEBV | UNTHREADED MOUNTING HOLE DIAMETER0 120 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ELECTROMAGNETIC | AKDX | WINDING QUANTITY1 |
ELECTROMAGNETIC | CQYJ | MOUNTING FACILITY PATTERNIN-LINE SINGLE MOUNTING FACILITY |
ELECTROMAGNETIC | CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE750 0 MILLIAMPERES DC RESISTIVE LOAD |
ELECTROMAGNETIC | CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS28 0 DC |
ELECTROMAGNETIC | TTQY | TERMINAL TYPE AND QUANTITY8 PIN ALL FUNCTIONS |