Thank you for your interest in NSN part number MIL-C-39019-6 under NSN 5925013118707 on Click Aerospace. Click Aerospace is a website owned and operated by ASAP Semiconductor, offering customers access to an unparalleled inventory of premium parts that cater to a variety of industries and applications. Circuit Breaker is an item listed with the part number MIL-C-39019-6, and FSC 5925 Circuit Breakers and it is manufactured by Bofors Ab having CAGE Code S3715. This item, alongside the rest of our listed NSN parts, is readily available for purchase through our website now. Get started on the purchasing process today by filling out and submitting an Instant RFQ as provided through our website. Once received, a member of our staff will reach out to you in 15 minutes or less to offer a personalized quote based on your individual needs.
Note : We will not share your information to any third parties.
Click Aerospace is a leading independent distributor of NSN part MIL-C-39019-6, and we can help you procure NSN components such as 5925013118707 and many more. The quality of our inventory is of the utmost importance to us, and thus we choose to only source our parts from global manufacturers like Bofors Ab. Get started with a competitive quote today when you submit an Instant RFQ and experience how we are revolutionizing the parts procurement process.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-311-8707 Item Description: CIRCUIT BREAKER | 5925 | 013118707 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
MIL-C-39019/6 | 5 | 1 | 4 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
ABXD | BUSHING LENGTH | 0.380 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.500 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.875 INCHES MAXIMUM |
ADTV | CASE MATERIAL | METAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.906 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.625 INCHES NOMINAL |
AEFN | NONTURN DEVICE LOCATION | AT 3 OCLOCK AND AT 9 OCLOCK |
AEFP | NONTURN DEVICE RADIUS | 0.625 INCHES NOMINAL |
AEFQ | NONTURN DEVICE LENGTH | 0.130 INCHES NOMINAL |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.780 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 3 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS AND 50.0 DC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 300.0 AC ALL LOCATIONS AND 500.0 DC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
CRTK | SWITCH TERMINAL TYPE | TAB, SOLDER LUG |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 0.5 AC AND 0.5 DC |
FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 ALL LOCATIONS |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.130 MINIMUM AT 200 PCT ALL LOCATIONS AND 1.300 MAXIMUM AT 200 PCT ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HERMETICALLY SEALED |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 120.0 AC AND 50.0 DC |
THSD | THREAD SERIES DESIGNATOR | UNEF |
AEFS | NONTURN DEVICE DIAMETER | 0.140 INCHES NOMINAL |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 250.0 MILLIAMPERES AC ALL LOCATIONS AND 250.0 MILLIAMPERES DC ALL LOCATIONS |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-39019 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI |
TTQY | TERMINAL TYPE AND QUANTITY | 6 WIRE HOOK |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-C-39019/6 GOVERNMENT SPECIFICATION |
Glad You Chose Click Aerospace as Your Parts Distributor Website today. We Hope that You Will Remember Us the Next Time You’re Looking for Required Parts.
Request for Quote
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |