Thank you for your interest in NSN part number B14L-5105-0178A under NSN 6130012547958 on Click Aerospace. Click Aerospace is a website owned and operated by ASAP Semiconductor, offering customers access to an unparalleled inventory of premium parts that cater to a variety of industries and applications. Power Supply is an item listed with the part number B14L-5105-0178A, and FSC 6130 Converters Electrical Nonrotating and it is manufactured by Fujitsu Microelectronics Inc having CAGE Code 61271. This item, alongside the rest of our listed NSN parts, is readily available for purchase through our website now. Get started on the purchasing process today by filling out and submitting an Instant RFQ as provided through our website. Once received, a member of our staff will reach out to you in 15 minutes or less to offer a personalized quote based on your individual needs.
Note : We will not share your information to any third parties.
Click Aerospace is a leading independent distributor of NSN part B14L-5105-0178A, and we can help you procure NSN components such as 6130012547958 and many more. The quality of our inventory is of the utmost importance to us, and thus we choose to only source our parts from global manufacturers like Fujitsu Microelectronics Inc. Get started with a competitive quote today when you submit an Instant RFQ and experience how we are revolutionizing the parts procurement process.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-254-7958 Item Description: Power Supply | 6130 | 012547958 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
B14l-5105-0178a | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 9.450 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3.780 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 8.460 INCHES NOMINAL |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | 10000.0 FEET |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE 1ST OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 2ND OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 3RD OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 4TH OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 5TH OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 100.0 AC POUNDS PER HOUR WET 5TH OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 115.0 AC POUNDS PER HOUR WET 4TH OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 120.0 AC POUNDS PER HOUR WET 3RD OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 220.0 AC POUNDS PER HOUR WET 2ND OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 240.0 AC POUNDS PER HOUR WET 1ST OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -24.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 115.0 AC VOLTS NOMINAL 4TH POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 24.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 50.0 HERTZ MINIMUM 5TH OPERATING POWER RQMT AND 60.0 HERTZ MAXIMUM 5TH OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 50.0 HERTZ NOMINAL 1ST OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 50.0 HERTZ NOMINAL 2ND OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 50.0 HERTZ NOMINAL 3RD OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 60.0 HERTZ NOMINAL 4TH OPERATING POWER RQMT |
APTS | OUTPUT FREQUENCY RATING | 60.0 HERTZ NOMINAL 4TH POWER OUTPUT |
AYNH | OPERATING AMBIENT TEMP RANGE | +0.1/+50.0 DEG CELSIUS |
BGHX | OUTPUT CONTROL QUANTITY | 2 1ST POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 2 2ND POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 2 3RD POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 1ST POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 2ND POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 300.0 AC MILLIAMPERES NOMINAL 4TH POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 4.0 DC AMPERES NOMINAL 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 4.2 DC AMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 4.8 DC AMPERES NOMINAL 2ND POWER OUTPUT |
CWGN | OUTPUT PHASE | SINGLE 4TH POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 3 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 3 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 3 3RD POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER STUD 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER STUD 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER STUD 3RD POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | SOLDER STUD 1ST OPERATING POWER RQMT |
CWHQ | INPUT CONNECTION TYPE | SOLDER STUD 2ND OPERATING POWER RQMT |
CWHQ | INPUT CONNECTION TYPE | SOLDER STUD 3RD OPERATING POWER RQMT |
CWHQ | INPUT CONNECTION TYPE | SOLDER STUD 4TH OPERATING POWER RQMT |
CWHQ | INPUT CONNECTION TYPE | SOLDER STUD 5TH OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 4 1ST OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 4 2ND OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 4 3RD OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 4 4TH OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 4 5TH OPERATING POWER RQMT |