Thank you for your interest in NSN part number A3-14690 under NSN 5950004658290 on Click Aerospace. Click Aerospace is a website owned and operated by ASAP Semiconductor, offering customers access to an unparalleled inventory of premium parts that cater to a variety of industries and applications. Transformer Power is an item listed with the part number A3-14690, and FSC 5950 Coils and Transformers and it is manufactured by Raytheon Company having CAGE Code 37695. This item, alongside the rest of our listed NSN parts, is readily available for purchase through our website now. Get started on the purchasing process today by filling out and submitting an Instant RFQ as provided through our website. Once received, a member of our staff will reach out to you in 15 minutes or less to offer a personalized quote based on your individual needs.
Note : We will not share your information to any third parties.
Click Aerospace is a leading independent distributor of NSN part A3-14690, and we can help you procure NSN components such as 5950004658290 and many more. The quality of our inventory is of the utmost importance to us, and thus we choose to only source our parts from global manufacturers like Raytheon Company. Get started with a competitive quote today when you submit an Instant RFQ and experience how we are revolutionizing the parts procurement process.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-465-8290 Item Description: Transformer Power | 5950 | 004658290 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
A3-14690 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.748 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.752 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.310 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.314 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 1.875 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.750 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.380 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.2 AMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 310.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 310.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 480.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 16.4 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY3.5 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY3.5 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 16.4 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY41.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 41.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 41.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY3.5 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY16.4 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 11.40 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY11.40 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 34.20 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 34.20 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY11.40 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY34.20 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 34.20 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY11.40 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY11.40 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 34.20 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY34.20 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING AND FIVE SECONDARY WINDINGS |
TEST | TEST DATA DOCUMENT | 37695-328720 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 19 TURRET |