Thank you for your interest in NSN part number 3019954-001 under NSN 5950003940659 on Click Aerospace. Click Aerospace is a website owned and operated by ASAP Semiconductor, offering customers access to an unparalleled inventory of premium parts that cater to a variety of industries and applications. Transformer Power is an item listed with the part number 3019954-001, and FSC 5950 Coils and Transformers and it is manufactured by Robert M Hadley Company Inc having CAGE Code 72964. This item, alongside the rest of our listed NSN parts, is readily available for purchase through our website now. Get started on the purchasing process today by filling out and submitting an Instant RFQ as provided through our website. Once received, a member of our staff will reach out to you in 15 minutes or less to offer a personalized quote based on your individual needs.
Note : We will not share your information to any third parties.
Click Aerospace is a leading independent distributor of NSN part 3019954-001, and we can help you procure NSN components such as 5950003940659 and many more. The quality of our inventory is of the utmost importance to us, and thus we choose to only source our parts from global manufacturers like Robert M Hadley Company Inc. Get started with a competitive quote today when you submit an Instant RFQ and experience how we are revolutionizing the parts procurement process.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-394-0659 Item Description: Transformer Power | 5950 | 003940659 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
3019954-001 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.609 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.641 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.109 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.437 INCHES MINIMUM AND 3.562 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.937 INCHES MINIMUM AND 3.062 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 4.687 INCHES MINIMUM AND 4.875 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 105.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 2.5 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 2.5 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY10.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY5.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 5.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY2.5 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 5.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY20.0 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY10.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 0.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 0.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY2.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY1.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 1.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY0.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 1.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY4.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY2.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY4.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; SIX SECONDARY WINDINGS,SIXTH SECONDARY HAS MULTIPLE TAPS W/O CENTER TAP |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 23 SOLDER STUD |
Glad You Chose Click Aerospace as Your Parts Distributor Website today. We Hope that You Will Remember Us the Next Time You’re Looking for Required Parts.
Request for Quote
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |