Thank you for your interest in NSN part number 2A2-244 under NSN 5950005819199 on Click Aerospace. Click Aerospace is a website owned and operated by ASAP Semiconductor, offering customers access to an unparalleled inventory of premium parts that cater to a variety of industries and applications. Transformer Power is an item listed with the part number 2A2-244, and FSC 5950 Coils and Transformers and it is manufactured by Rohde And Schwarz Engineering Andsales having CAGE Code C2201. This item, alongside the rest of our listed NSN parts, is readily available for purchase through our website now. Get started on the purchasing process today by filling out and submitting an Instant RFQ as provided through our website. Once received, a member of our staff will reach out to you in 15 minutes or less to offer a personalized quote based on your individual needs.
Note : We will not share your information to any third parties.
Click Aerospace is a leading independent distributor of NSN part 2A2-244, and we can help you procure NSN components such as 5950005819199 and many more. The quality of our inventory is of the utmost importance to us, and thus we choose to only source our parts from global manufacturers like Rohde And Schwarz Engineering Andsales. Get started with a competitive quote today when you submit an Instant RFQ and experience how we are revolutionizing the parts procurement process.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-581-9199 Item Description: Transformer Power | 5950 | 005819199 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
2a2-244 | 6 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.094 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.890 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.922 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTD | MOUNTING SLOT WIDTH | 0.213 INCHES MINIMUM SINGLE GROUP AND 0.223 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 1.0 KILOHERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 5.000 INCHES MAXIMUM |
ADAT | BODY WIDTH | 4.031 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 4.500 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 170.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.8 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 300.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 600.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 10.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 17.6 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 3.78 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 565.5 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 45.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY AND 705.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY AND 1.29 AC KILOVOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY AND 1.88 AC KILOVOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 5.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 56.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING AND SIX SECONDARY WINDINGS |
TEST | TEST DATA DOCUMENT | 56232-631198 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
TTQY | TERMINAL TYPE AND QUANTITY | 19 TAB, SOLDER LUG |