Thank you for your interest in NSN part number MT0075I under NSN 5950014884471 on Click Aerospace. Click Aerospace is a website owned and operated by ASAP Semiconductor, offering customers access to an unparalleled inventory of premium parts that cater to a variety of industries and applications. Transformer Power is an item listed with the part number MT0075I, and FSC 5950 Coils and Transformers and it is manufactured by Siemens Energy And Automation Inc having CAGE Code 0ACF4. This item, alongside the rest of our listed NSN parts, is readily available for purchase through our website now. Get started on the purchasing process today by filling out and submitting an Instant RFQ as provided through our website. Once received, a member of our staff will reach out to you in 15 minutes or less to offer a personalized quote based on your individual needs.
Note : We will not share your information to any third parties.
Click Aerospace is a leading independent distributor of NSN part MT0075I, and we can help you procure NSN components such as 5950014884471 and many more. The quality of our inventory is of the utmost importance to us, and thus we choose to only source our parts from global manufacturers like Siemens Energy And Automation Inc. Get started with a competitive quote today when you submit an Instant RFQ and experience how we are revolutionizing the parts procurement process.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-488-4471 Item Description: TRANSFORMER,POWER | 5950 | 014884471 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
MT0075I | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 89.0 MILLIMETERS NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 64.0 MILLIMETERS NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 64.0 MILLIMETERS NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 65.0 MILLIMETERS NOMINAL |
ABMK | OVERALL WIDTH | 76.0 MILLIMETERS NOMINAL |
ABTD | MOUNTING SLOT WIDTH | 5.0 MILLIMETERS NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT AND 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 0.34 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 0.68 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 75.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY INPUT |
CWJS | WINDING OPERATING VOLTAGE | 110.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 220.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 380.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT AND 400.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT AND 415.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT |
TTQY | TERMINAL TYPE AND QUANTITY | 8 THREADED STUD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 89.0 MILLIMETERS NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 64.0 MILLIMETERS NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 64.0 MILLIMETERS NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 65.0 MILLIMETERS NOMINAL |
ABMK | OVERALL WIDTH | 76.0 MILLIMETERS NOMINAL |
ABTD | MOUNTING SLOT WIDTH | 5.0 MILLIMETERS NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT AND 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 0.34 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 0.68 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 75.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY INPUT |
CWJS | WINDING OPERATING VOLTAGE | 110.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 220.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 380.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT AND 400.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT AND 415.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT |
TTQY | TERMINAL TYPE AND QUANTITY | 8 THREADED STUD |